Platform

Every module, and the question it answers.

Rackline is one record with a set of lenses on it. Each module below is a way of asking the same facts a different question — and every one of them is reachable from the console, the API and the agent interface.

Inventory

What is here, and where?

The spine everything hangs from: sites grouped into regions, campuses and availability zones; rooms; cabinets; and every device in them.

  • Asset records with tagging, custom fields and attachments
  • Rack elevations and a floor plan
  • Licences, supports and lifecycle states with audited changes
  • Bulk edit, CSV import and export
Power

Where does each watt come from?

A chain you can walk from a cabinet back to the switchgear, with the arithmetic done for you.

  • Circuits, outlets, PDUs, power domains and redundancy groups
  • Every cord on every device, and the circuits behind it
  • Free kW per circuit and per rack, with feeders carrying what their branches carry
  • Blast radius, single-corded and falsely redundant reports
Cooling

How does the heat leave?

Facility and technology loops modelled as they run, including the liquid side.

  • Cooling loops, CDUs and units, with capacity in kW and in L/min
  • Manifolds, coolant connectors and cold-plate attributes
  • Leak detectors, pumps and filters with their own service clocks
  • Racks blocked for lack of a manifold port, and liquid racks nobody is watching
Connectivity

Is every rail where it should be?

The physical layer as intent, so a wrong cable is a finding rather than a surprise.

  • Cables, patch panels and end-to-end path tracing with a length budget
  • Transceivers by serial, lot and date code, with recall queries
  • Links with rated and negotiated speed, dead lanes and flap counts
  • Fabrics and rail attachments, declared against discovered
Accelerators

Which GPUs, and in what state?

The part that actually fails, tracked as a unit rather than as a line on a chassis.

  • Accelerators keyed on GPU UUID, on baseboards and compute trays
  • Firmware inventory against baselines, with drift kept apart from coverage gaps
  • Health events, remap budgets and acceptance runs
  • MIG partitions, and out-of-band ingest that works with the node powered off
Capacity

What fits, and what does it leave?

Four budgets — U, kW, kg and L/min — checked at placement and reported after.

  • Rack ceilings for power, weight and cooling type
  • Per-model power envelopes and weights
  • Cluster and scalable-unit design against installed
  • Measured peaks preferred over nameplate, when fresh
Digital twin

What does the hall look like, right now?

A three-dimensional drawing of a site, from the inventory and kept current.

  • Cabinets, devices, PDU rails, plant, detectors and sensors, at real scale
  • Status, Kinds, Heat and Cooling views
  • The cables the inventory holds, drawn as they run
  • One request draws a site, however many cabinets it holds
Work orders

Is this change safe, and what happened?

Move, add, change and dispose as one piece of work with a plan, a window and a record.

  • Eleven preflight checks, held as they stood at approval
  • Maintenance windows that distinguish planned work from failure
  • Per-machine outcomes, retry of only what failed
  • Rackline holds your ticket id; it never invents one
Many sites

One estate, as many buildings as you have.

Most questions about a multi-site estate are really about one building. Every report takes a site or a group of sites, every row names where it is, and the console can be put into one site and stay there.

  • Sites grouped into regions, campuses and availability zones
  • A relationship that would cross a building is refused, naming both sites
  • Access can be granted per site, and a user with no scope sees everything — narrowing is something you add, never something you forget
  • Query counts that stay flat as sites are added
Next

See it with your own estate.