Every module, and the question it answers.
Rackline is one record with a set of lenses on it. Each module below is a way of asking the same facts a different question — and every one of them is reachable from the console, the API and the agent interface.
What is here, and where?
The spine everything hangs from: sites grouped into regions, campuses and availability zones; rooms; cabinets; and every device in them.
- Asset records with tagging, custom fields and attachments
- Rack elevations and a floor plan
- Licences, supports and lifecycle states with audited changes
- Bulk edit, CSV import and export
Where does each watt come from?
A chain you can walk from a cabinet back to the switchgear, with the arithmetic done for you.
- Circuits, outlets, PDUs, power domains and redundancy groups
- Every cord on every device, and the circuits behind it
- Free kW per circuit and per rack, with feeders carrying what their branches carry
- Blast radius, single-corded and falsely redundant reports
How does the heat leave?
Facility and technology loops modelled as they run, including the liquid side.
- Cooling loops, CDUs and units, with capacity in kW and in L/min
- Manifolds, coolant connectors and cold-plate attributes
- Leak detectors, pumps and filters with their own service clocks
- Racks blocked for lack of a manifold port, and liquid racks nobody is watching
Is every rail where it should be?
The physical layer as intent, so a wrong cable is a finding rather than a surprise.
- Cables, patch panels and end-to-end path tracing with a length budget
- Transceivers by serial, lot and date code, with recall queries
- Links with rated and negotiated speed, dead lanes and flap counts
- Fabrics and rail attachments, declared against discovered
Which GPUs, and in what state?
The part that actually fails, tracked as a unit rather than as a line on a chassis.
- Accelerators keyed on GPU UUID, on baseboards and compute trays
- Firmware inventory against baselines, with drift kept apart from coverage gaps
- Health events, remap budgets and acceptance runs
- MIG partitions, and out-of-band ingest that works with the node powered off
What fits, and what does it leave?
Four budgets — U, kW, kg and L/min — checked at placement and reported after.
- Rack ceilings for power, weight and cooling type
- Per-model power envelopes and weights
- Cluster and scalable-unit design against installed
- Measured peaks preferred over nameplate, when fresh
What does the hall look like, right now?
A three-dimensional drawing of a site, from the inventory and kept current.
- Cabinets, devices, PDU rails, plant, detectors and sensors, at real scale
- Status, Kinds, Heat and Cooling views
- The cables the inventory holds, drawn as they run
- One request draws a site, however many cabinets it holds
Is this change safe, and what happened?
Move, add, change and dispose as one piece of work with a plan, a window and a record.
- Eleven preflight checks, held as they stood at approval
- Maintenance windows that distinguish planned work from failure
- Per-machine outcomes, retry of only what failed
- Rackline holds your ticket id; it never invents one
One estate, as many buildings as you have.
Most questions about a multi-site estate are really about one building. Every report takes a site or a group of sites, every row names where it is, and the console can be put into one site and stay there.
- Sites grouped into regions, campuses and availability zones
- A relationship that would cross a building is refused, naming both sites
- Access can be granted per site, and a user with no scope sees everything — narrowing is something you add, never something you forget
- Query counts that stay flat as sites are added