AI factory operations

Run your AI factory from one record of truth.

Rackline is the system of record and operations console for AI data centres. It knows every cabinet, circuit, coolant loop, cable and GPU, checks them against what you intended, and tells you what is wrong before a training run does.

Self-hosted · Open source foundation · Console, API and agent access

Illustrative example · not customer data

The problem

A GPU cabinet is not a rack of servers. It is a power plant, a plumbing run and a fabric.

Capacity is four budgets — space, power, weight and coolant — and a spreadsheet tracks one of them. The parts that fail are no longer the chassis but the GPU, the transceiver and the baseboard, and the worst failures stay green: a link trained at half its rated speed is up, passing traffic, and never raises an alert.

Without RacklineWaiting on someone to remember
Spreadsheet
Diagram, last updatedby hand
Monitoring
“Is that port right?”by hand
Change ticket
Walk the floorby hand
With RacklineIntent, checked continuously
Recordwhat exists
Budgetswhat fits
Checkswhat is wrong
Work orderwhat changes
Preflightis it safe
Evidencewhat happened
52%

of interruptions in a 54-day, 16,384-GPU Llama 3 405B training run were GPU or HBM3 failures. Two were CPUs.

Meta, Llama 3 · 419 events
5,000+

link flaps a day on a large training network — and 0.057% of NIC-to-switch links fail every month.

Alibaba HPN · SIGCOMM ’24
10.4%

of nodes were defective, found only by proactive validation. Healthy-looking is not the same as healthy.

Microsoft SuperBench · ATC ’24
1,500kg

for a filled liquid-cooled rack, in halls designed for 500–750 kg a position. Weight is a budget too.

Rack-scale systems · filled weight

Figures are from operators’ published papers and vendor documentation. Sources on request.

Capacity

Four budgets, not one.

Rackline tracks every budget a placement can break, refuses a placement that would overrun one, and tells you why. Measured peaks are preferred over nameplate figures, and an unrecorded ceiling means “unknown” — never “unlimited”.

Uspace

Rack units

Free units in the rack, and the footprint around it, checked at the moment of placement.

kWpower

Power

Design ceiling per rack against nameplate and measured peak, summed up the chain from outlet to breaker.

kgweight

Floor loading

Declared weights against each rack’s ceiling, including chassis quoted empty and blades counted separately.

L/mincoolant

Coolant

CDU capacity in kW and in flow, checked against each other — a rating that assumes the wrong delta-T overcommits by exactly that ratio.

How it works

From the cabinet to the change, in five stages.

Each stage hands what it knows to the next. Nothing here is a separate product: it is one record, asked different questions.

Stage 1 of 5 · Record

Model what is actually there.

Sites, rooms, cabinets and the devices in them, and everything that feeds and connects them. Each one is a row you can query, not a line in a diagram.

  • The power chain from utility to outlet, and every cord on it
  • Cooling loops, CDUs, manifolds and leak detectors
  • Fabrics, cables, patch panels and transceivers tracked by lot
  • Accelerators by UUID, on their baseboards and compute trays
  • Firmware inventoried against baselines, health as latched conclusions
Digital twin

Stand in the cold aisle without leaving the browser.

The whole site, drawn at real scale from the same rows as everything else: 600 mm cabinets, 44.45 mm to the U, every device at its position, every cable where the inventory says it runs.

  • Status, Kinds, Heat and Cooling views over one scene
  • Click a cabinet and the camera flies to it and opens its record
  • Re-reads the inventory every thirty seconds, so a change appears without a reload
  • Nothing on screen that is not a row. A cabinet with no recorded footprint is drawn at standard size and says not recorded
StatusKindsHeatCooling
B07 · 1.84 kW of 3029.5 °C intake · rear door
In useRunning hotSelectedCold aisle

Illustrative drawing · the console renders your own site

For every role

One record, asked the right question.

The people who keep an AI factory running ask very different things of the same facts. Rackline answers each in their own terms, from the same rows.

Data centre operations

Where is it, and is it safe to touch?

Locate any asset, see its rack and its power path, and plan the move as a work order that checks itself first.

Network and fabric

Is every rail where it should be?

Declared against discovered, per host and per plane. Wrong switch, wrong port and undeclared are different findings and are kept apart.

Facility and capacity

How much headroom is really left?

Free kW per circuit and per rack, coolant capacity, floor loading and cooling service due — for one site or all of them.

GPU and platform

Which units are unhealthy, and since when?

Firmware drift, health events, remap budgets and acceptance runs per accelerator, with placement history that survives a part being moved.

Security and access

Who can see which site?

Permissions per person and visibility scopes per site. Access is narrowed by adding a scope, never by forgetting to.

Leadership

What is wrong, in one page?

The landing page shows what needs attention rather than what exists, and every number is one click from the rows behind it.

For agents

An agent that can operate the estate, as someone in particular.

Rackline speaks the Model Context Protocol. An external agent can answer questions about the estate and propose or run work — with exactly the permissions and site scopes of the account behind its token, and nothing more.

  • Questions, not endpoints: site_summary, estate_findings, power_path, preflight_work_order
  • A wrong filter is an error, not a silent full table
  • Partial failure reads as partial failure
  • A read-only mode removes every write tool

How access and audit work

An agent asksIllustrative
# Which sites do I have, and what is wrong in the first?
list_sites()
estate_findings(site=1)

→ Undertrained links ........ 4
→ Firmware off baseline ..... 2
→ Single-corded devices ..... 3

# Trace the power behind one machine
power_path(base_object_id=214)

# Plan, don't just act
create_work_order(name="Move B07 to row C",
                  kind="move", site=1, racks=[7])
preflight_work_order(id=12)
Get started

Sign in and look around.

Your estate, in one console: records, racks, the twin, and a landing page that tells you what needs attention. Accounts are created by an administrator.