Run your AI factory from one record of truth.
Rackline is the system of record and operations console for AI data centres. It knows every cabinet, circuit, coolant loop, cable and GPU, checks them against what you intended, and tells you what is wrong before a training run does.
Self-hosted · Open source foundation · Console, API and agent access
- Firmware driftRunning off the active baseline2
- Undertrained linksUp, passing traffic, at half their rated speed4
- Falsely redundantTwo cords from the same source3
- Single-cordedOne power feed, one failure away3
- Unwatched liquid racksEvery liquid-cooled rack has detection0
Illustrative example · not customer data
A GPU cabinet is not a rack of servers. It is a power plant, a plumbing run and a fabric.
Capacity is four budgets — space, power, weight and coolant — and a spreadsheet tracks one of them. The parts that fail are no longer the chassis but the GPU, the transceiver and the baseboard, and the worst failures stay green: a link trained at half its rated speed is up, passing traffic, and never raises an alert.
of interruptions in a 54-day, 16,384-GPU Llama 3 405B training run were GPU or HBM3 failures. Two were CPUs.
Meta, Llama 3 · 419 eventslink flaps a day on a large training network — and 0.057% of NIC-to-switch links fail every month.
Alibaba HPN · SIGCOMM ’24of nodes were defective, found only by proactive validation. Healthy-looking is not the same as healthy.
Microsoft SuperBench · ATC ’24for a filled liquid-cooled rack, in halls designed for 500–750 kg a position. Weight is a budget too.
Rack-scale systems · filled weightFigures are from operators’ published papers and vendor documentation. Sources on request.
Four budgets, not one.
Rackline tracks every budget a placement can break, refuses a placement that would overrun one, and tells you why. Measured peaks are preferred over nameplate figures, and an unrecorded ceiling means “unknown” — never “unlimited”.
Rack units
Free units in the rack, and the footprint around it, checked at the moment of placement.
Power
Design ceiling per rack against nameplate and measured peak, summed up the chain from outlet to breaker.
Floor loading
Declared weights against each rack’s ceiling, including chassis quoted empty and blades counted separately.
Coolant
CDU capacity in kW and in flow, checked against each other — a rating that assumes the wrong delta-T overcommits by exactly that ratio.
From the cabinet to the change, in five stages.
Each stage hands what it knows to the next. Nothing here is a separate product: it is one record, asked different questions.
Model what is actually there.
Sites, rooms, cabinets and the devices in them, and everything that feeds and connects them. Each one is a row you can query, not a line in a diagram.
- The power chain from utility to outlet, and every cord on it
- Cooling loops, CDUs, manifolds and leak detectors
- Fabrics, cables, patch panels and transceivers tracked by lot
- Accelerators by UUID, on their baseboards and compute trays
- Firmware inventoried against baselines, health as latched conclusions
Know what fits before you buy it.
Every rack carries its ceilings, every model its power and weight. A placement that would break a budget is refused with the reason, in the same breath as the rack-unit check.
- Design power, weight and cooling type per rack
- Nameplate, idle, typical and peak power per model
- Measured peaks written back from monitoring, used when fresh
- Cluster and scalable-unit design against what is installed
- Free kW per circuit, rolled up the chain
- Free kW per rack, scoped by the circuits that feed it
- Coolant: capacity in kW and in L/min, cross-checked
- Unrated means unknown — never zero, never unlimited
Find what is wrong, not just what exists.
The questions that matter are joins and aggregations, and a flat table can express neither. Rackline asks them for you and puts the answers on the first page.
- Firmware off its baseline — and the baseline gaps, kept apart
- Links trained below their rated speed or lanes
- Devices corded twice to the same source
- Single-corded devices
- Rails miscabled against what was declared
- Liquid-cooled racks with no leak detection
- Cooling parts overdue for service
- BMCs that cannot be reached
A finding never disappears when it clears: zero still renders, so a clean check can be told from one nobody wired up. Every report takes a site.
Plan the work, then prove it.
A move, add, change or disposal is one work order: its scope, its ordered steps, its window and its outcome — with the question “is this safe?” asked at the moment somebody is about to act.
Eleven preflight checks: same site, blast radius, power, rack units, redundancy, windows, dependencies, and more. The result is held, so what was true at approval is what the record says.
- A failure blocks until overridden; an override costs a reason and stays on the order
- Steps run per machine, each tied to the history row that proves it
- A refused machine stops the order and says which later steps never started
- Retry touches only what failed
Nothing is rolled back, and nothing is claimed. A half-done order reads as exactly that.
Hand it to people and agents.
One set of rules for everyone who touches the estate. The console, the REST API and the agent interface all go through the same permission checks and the same site scopes.
- A console for operators: records, racks, floor plan, twin
- A REST API with token authentication
- CSV import, with a dry run before anything is written
- An MCP server: twenty-eight tools shaped like questions
- Each agent acts as the person whose token it carries
- Every call is logged with who made it and how it ended
Stand in the cold aisle without leaving the browser.
The whole site, drawn at real scale from the same rows as everything else: 600 mm cabinets, 44.45 mm to the U, every device at its position, every cable where the inventory says it runs.
- Status, Kinds, Heat and Cooling views over one scene
- Click a cabinet and the camera flies to it and opens its record
- Re-reads the inventory every thirty seconds, so a change appears without a reload
- Nothing on screen that is not a row. A cabinet with no recorded footprint is drawn at standard size and says not recorded
Illustrative drawing · the console renders your own site
One record, asked the right question.
The people who keep an AI factory running ask very different things of the same facts. Rackline answers each in their own terms, from the same rows.
Where is it, and is it safe to touch?
Locate any asset, see its rack and its power path, and plan the move as a work order that checks itself first.
Is every rail where it should be?
Declared against discovered, per host and per plane. Wrong switch, wrong port and undeclared are different findings and are kept apart.
How much headroom is really left?
Free kW per circuit and per rack, coolant capacity, floor loading and cooling service due — for one site or all of them.
Which units are unhealthy, and since when?
Firmware drift, health events, remap budgets and acceptance runs per accelerator, with placement history that survives a part being moved.
Who can see which site?
Permissions per person and visibility scopes per site. Access is narrowed by adding a scope, never by forgetting to.
What is wrong, in one page?
The landing page shows what needs attention rather than what exists, and every number is one click from the rows behind it.
An agent that can operate the estate, as someone in particular.
Rackline speaks the Model Context Protocol. An external agent can answer questions about the estate and propose or run work — with exactly the permissions and site scopes of the account behind its token, and nothing more.
- Questions, not endpoints: site_summary, estate_findings, power_path, preflight_work_order
- A wrong filter is an error, not a silent full table
- Partial failure reads as partial failure
- A read-only mode removes every write tool
# Which sites do I have, and what is wrong in the first? list_sites() estate_findings(site=1) → Undertrained links ........ 4 → Firmware off baseline ..... 2 → Single-corded devices ..... 3 # Trace the power behind one machine power_path(base_object_id=214) # Plan, don't just act create_work_order(name="Move B07 to row C", kind="move", site=1, racks=[7]) preflight_work_order(id=12)
Sign in and look around.
Your estate, in one console: records, racks, the twin, and a landing page that tells you what needs attention. Accounts are created by an administrator.